800 - 10,800 GPD

Typical Model with Options
|

Typical Standard Model
|
FEED WATER PARAMETERS:
Temperature
85°F maximum Pressure
40 - 80 psi maximum TDS
2000 ppm maximum. If higher, consult factory Iron
tolerence 0.5 ppm maximum Hydrogen
sulfide must be removed Silica
tolerance can not be higher than 125 ppm in the concentrate stream.
Anti-scalant should be considered for any levels over 75 ppm. Turbidity
should be removed Hardness
over 10gpg should be softened.
OPERATING PARAMETERS:
Operating pressure
200 psi maximum Water
recov-ery is facotry set at 33 - 35% pH
range 3 - 11 Flow
rates are determined by the membrane mfgr's. testing criteriea of
1500 ppm Nacl solution, 77F water temperature, 225 psi at 10 - 15%
recovery. Actual flow rates may vary depending on the pre-treatment
used, water conditions, system size and applied pressure. |
|
|
| |
|
|
|
| • |
NEMA 4 fibreglass enclosure |
• |
Fused control circuit |
| • |
Off/On switch |
• |
24 volt level control circuit |
| • |
Dual level float switches |
• |
Time delay start |
| • |
Low pressure switch |
• |
30 amp motor contractor |
| • |
Low pressure bypass delay |
|
|
| |
|
Lights: power, running, low pressure, tank
full
|
|
MODEL
|
GPD
|
MEMBRANE
|
MOTOR
|
PUMP
|
PIPING
|
DIMENSIONS
|
|
|
|
|
|
inlet
|
waste
|
prod
|
|
|
FMV 800
|
800
|
4" x 21"
|
1 ea.
|
1/2 HP
|
rotary vane
|
1/2"
|
1/2"
|
1/2"
|
24" x 29" x 49"H
|
| FMV - 1 |
1500 - 1800
|
4" x 40"
|
1 ea.
|
1 HP
|
rotary vane
|
3/4"
|
1/2"
|
1/2"
|
24" x 29" x 57"H
|
| FMV - 2 |
3000 - 3600
|
4" x 40"
|
2 ea.
|
2 HP
|
multi-stage
|
1"
|
1/2"
|
1/2"
|
24" x 29" x 57"H
|
|
FMV - 3
|
4500 - 5400
|
4" x 40"
|
3 ea.
|
2 HP
|
multi-stage
|
1"
|
1/2"
|
1/2"
|
29" x 29" x 61"H
|
| FMV - 4 |
6000 - 7200
|
4" x 40"
|
4 ea.
|
3 HP
|
multi-stage
|
1"
|
1/2"
|
1/2"
|
29" x 29" x 61"H
|
| FMV - 5 |
7500 - 9000
|
4" x 40"
|
5 ea.
|
3 HP
|
multi-stage
|
1"
|
1/2"
|
1/2"
|
29" x 29" x 61"H
|
|
FMV - 6
|
9000 - 10800
|
4" x 40"
|
6 ea.
|
2 HP
|
multi-stage
|
1"
|
1/2"
|
1/2"
|
29" x 29" x 61"H
|
|